Connect the power supply and equipment, the measuring temperature is displayed, press the “SET” button, press ” + or – ” to set the desired temperature (long press ” + or – ” to quickly increase or decrease), press “SET” to confirm the setting and return, controller automatically performs the relay ON/OFF.the thermostat output is 10A relay, meet a variety of high-power loads,
-
LED Indicator: LED off indicates the relay off; Lighting,indicates the relay is closed.
-
Digital LED Tubes: “LL” indicates sensor open, “HH” indicates overrange, the relay will be forcibly disconnected; “—” indicates high temperature alarm
-
Long press the “SET” button to enter the main menu settings, press ” + or – ” to switching between P0-P6,then long press “SET” or 10 seconds without keystrokes to confirm the setting and return.
-
When the Thermostat is power off, long press “- or +”, you can restore the factory settings